• Ultrasonic Hifu ceramic
  • Ultrasonic Hifu ceramic
  • Ultrasonic Hifu ceramic

Ultrasonic Hifu ceramic

Model No.︰

-

Brand Name︰

Ginpertec

Country of Origin︰

China

Unit Price︰

US $ 1 / pc

Minimum Order︰

5 pc

Share on:

Product Description

1Mhz~10Mhz  Medical Piezoelectric Transducer

Product user

Ultrasonic rhytidectomy or medical treatment of cancer. Core components of ultrasonic scalpel and ultrasonic treatment instrument

Product features

The principle of ultrasonic rhytidectomy: through the cluster heat transfer mode of lattice, the skin is circumvent, and under the premise of not cutting the epidermis, the ultrasonic scalpel hairdressing to explore the matrix molecular energy waves that vibrate up to 400-700 million times per second to deep subcutaneous cell damage, and the depth of the hypodermic 1.5-4.5mm left right is directly affected by the deep layer. The fascia, which forms focusing surface in the fascia radio frequency electric field, strongly impacts the dermal tissue and produces the effect of electric field aggregation on the dermal tissue, raising the subcutaneous temperature to 60-75 degrees C, determining the effective heat damage of the heat in the dermal fiber layer, triggering the function of the body to start repairing the regenerated cells and repairing the fascia. The effect of pulling, removing wrinkles and tightening the skin.

The principle of ultrasound focused therapy: the energy of ultrasound in the non treated part of it is not enough to damage the tissue. At the focus of its focus, because of the high sound intensity, the temperature of the tissue rises to 60~100 C by the thermal effect of ultrasound, resulting in protein denaturation and irreversible coagulant necrosis of the tissue cells. Meanwhile, the interstitial fluid, intercellular fluid and the intracellular gas molecules are positive and negative by the cavitation effect of ultrasound. Under the action of phase, bubbles form, and then contract and expand, resulting in the final explosion, resulting in cell damage and necrosis.

Technical parameter

Frequency: 250KHZ,  1-10mhz  ,and so on

Type

Frequency

Capacitance

Dimension

ID/Focus distance

Peak power

 

Fs

CT(pF)

D*H(mm)

(mm)

(W)

GPF4-Ø75/Ø12×8-S40

250KHz

8000±10%

75*29

40/20.0

350

GPF4-Ø50/Ø12×8-S26.5

250KHz

3600±10%

50*20

27/15.0

250

GPF8-Ø24.0×2-SR20

1MHz

2400±10%

24.0*6.0

20/16.0

40

GPFF8-Ø23.2×2-SR20

1MHz

2000±10%

23.2*5.4

20/16.3

35

GPF8-Ø23.2×0.7-SR15

3MHz

6200±10%

23.2*5.6

15/10.0

25

GPF8-Ø23.2/Ø6×0.7-SR15

3MHz

5700±10%

23.2*5.4

15/10.0

20

GPF4-Ø23.2×0.7-SR15

3MHz

10000±10%

23.2*5.4

15/10.0

25

GPF4-Ø23.0×0.7-SR20

3MHz

8000±10%

23.0*4.5

20/16.3

25

GPF4-Ø20×0.7-SR20

3MHz

6500±10%

20.0*3.5

20/18.0

20

GPF4-Ø20×0.5-SR20

4.5MHz

8500±10%

20.0*3.2

20/18.0

18

GPF4-Ø20×0.3-SR20

6MHz

14400±10%

20.0*3.1

20/18.0

15

GPF4-Ø20×0.2-SR20

8MHz

16500±10%

20.0*3.0

20/18.0

12

GPF4-Ø15×0.3-SR30

6MHz

9500±10%

15.0*2.0

30/13.0

10

GPF4-Ø8×0.2-SR30

10MHz

6500±10%

8.0*0.5

30/14.5

10